784, 1753 and the two 1666 lofts came from holes in exported meshes, so each now also requires a mesh with no open or over-shared edge. On today's kernel 784 and both lofts are watertight; 1753's bowl, its rim cut by a cylinder, still has 3 open mesh edges. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
14 lines
984 B
JSON
14 lines
984 B
JSON
{
|
|
"sources": [
|
|
"tangency-labs/solidcraft#1666",
|
|
"tangency-labs/solidcraft#1670"
|
|
],
|
|
"what": "a loft from a 20x20 square to the same square turned 45 degrees, 30 mm higher: its four side faces are strongly twisted ruled patches, the case a two-triangle mesh gets visibly wrong",
|
|
"source": "analytic",
|
|
"method": "At height 30t the section is the polygon of (1-t)p_i + t q_i (p_i the square's corners at angles 45+90k deg, q_i those at 90+90k deg, both radius 10 sqrt 2). Its shoelace area is quadratic in t, so Simpson is exact: A0=A1=400, A(1/2)= 2 r^2 (1 - ... ) computed from the midpoint polygon (a square of circumradius r cos(22.5 deg): area 2 r^2 cos^2(22.5 deg) = 400 cos^2(22.5 deg)=341.42). V = 30/6 (400 + 4*341.4214 + 400) = 5*(2165.6854)=10828.427. Faces: 4 sides and 2 caps. Watertight: each body's mesh has no open or over-shared edge (the reports were holes in the exported mesh).",
|
|
"body_count": 1,
|
|
"volume_mm3": 10828.427,
|
|
"faces": 6,
|
|
"watertight": true
|
|
}
|