Files
solidcraft/tests/kernel-cases/sheet-metal/262-fold-a-tab-just-inside-its-root/expected.json
T
Brennen HerbruckandClaude Sonnet 5.5 3c465e6801 kernel-cases: sheet-metal fold cases from #262, #264, #638, #639, #685
Folds of tabs and plates, graded by closed form: a fold keeps the blank's
flat length, so V = flat area * t + theta * w * t^2 * (1/2 - K). Tabs
on one line (#264, #638), a tab on an L's inside edge (#639), a fold just
inside a tab root and a refusal at the root (#262), a fixed point on the
top face of a large plate (#685).

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
2026-10-27 02:28:45 -04:00

11 lines
731 B
JSON

{
"sources": [
"tangency-labs/solidcraft#262",
"tangency-labs/solidcraft#277"
],
"what": "a 20 x 20 tab folded 90 degrees on a line 1 mm inside its root, where the bend zone stays clear of the blank's outline",
"source": "analytic",
"method": "blank area 100*50 + 20*20 = 5400 mm2 at t = 0.8; the fold has width 20: a fold keeps the flat length of the blank, so a fold of angle th, inner radius R, thickness t and K-factor K over a width w takes a flat strip of BA = th(R+Kt) and puts a bend of volume th((R+t)^2-R^2)w/2 in its place: V = V_flat + th w t^2 (1/2 - K) (the bend's mid-surface lies at R+t/2, the neutral axis at R+Kt). V = 5400*0.8 + (pi/2)*20*0.64*0.06",
"body_count": 1,
"volume_mm3": 4321.206371578978
}