* claim: #6917
* Tests: the six timing assertions do not depend on the wall clock (#6917)
Six tests asserted on the wall clock. Their result depended on how loaded
the machine was and not only on the code under test: they passed on an idle
machine and failed when the test binaries ran beside each other, which is how
the suite runs (`cargo xtask test` starts every test binary at once).
CONTRIBUTING.md:196 says it: "Tests run beside each other on a busy machine,
so a test must not depend on wall-clock timing."
The change is confined to the six test files the issue names:
- geom: the tangent chain of a helix is a ratio (750 pieces against 3 000)
instead of a limit of 200 ms.
- io: the placement budget is spent inside the reader, so the clock is gone.
- ui-egui: the classification of many faces is a ratio (900 against 3 600)
instead of a limit of 10 s.
- engine: the clearance measurement drops its 30 s limit; the boolean that
gives up reports itself.
- engine: the fillet beside a modelled thread is a ratio (a 1 mm thread
against an 8 mm one) instead of a limit of 30 s.
- ui-egui: the window frame budget goes from 250 ms to 20 s, the limit #6072
gave its own probe.
The helper is the one #649 wrote, copied into the crates that need it, with
the noise of a run as a parameter.