Files
solidcraft/crates/kernel
Brennen HerbruckandClaude Opus 5.5 5014c4f17f kernel: with SOLIDCRAFT_KERNEL=smlib, STEP solids are SMLib's bodies
Each solid item of a STEP file goes through the schema 4 reader
(solidcraft_step::topology, at the file's units and uncertainty) into
SMLib through the flat converter, healed where SMLib's check refuses it,
and comes back as a kernel body; its faces keep the file faces they came
from. A solid the reader or SMLib refuses is not imported, with the
reason: there is no truck fallback on this path. truck's own reader is
unchanged and stays the default.

Test: the 17 step-conformance parts read into SMLib with their exact
volumes and face counts, every face traced to an ADVANCED_FACE; the three
NURBS parts stay refused by the reader (a loop across a closed spline
surface's seam), as on schema 4 today.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:28:47 -04:00
..