A sketch that failed (a dimension set negative by a parameter) left every
feature built on it with "unknown sketch 1 (it must come earlier in the
timeline)", which points at the timeline order. The evaluation now notes
the features that failed earlier in the pass, and a feature whose input
sketch is one of them fails with "sketch `Sketch1` failed: <its error>".
That result is never cached, since the cache key holds neither the
sketch's name nor its error: a second failing value or a rename shows
up at once.