2 commits, squashed; the originals stay reachable from tag archive/merge-main-develop.
- d63aa814f jyviko: threads: main's tapped-hole sizes and shaft turn-down on the reworked thread
- cfc393d68 jyviko: Main's new callers of the placing calls that now return their error
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DtL5M41G8Nua7HvuFPZkmJ
A path a design names (a linked design, a sketch text's font file) now
goes through one rule before any file call: a network location is
reached only once its server is allowed, a device path never. Update
Links and Open Linked Design ask first (Allow once / Always allow this
server / Cancel); Preferences > Design lists the allowed servers and
can allow every network location. component.links reports such a
link's found as unknown with a reason, without looking for it.
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
* claim: #6917
* Tests: the six timing assertions do not depend on the wall clock (#6917)
Six tests asserted on the wall clock. Their result depended on how loaded
the machine was and not only on the code under test: they passed on an idle
machine and failed when the test binaries ran beside each other, which is how
the suite runs (`cargo xtask test` starts every test binary at once).
CONTRIBUTING.md:196 says it: "Tests run beside each other on a busy machine,
so a test must not depend on wall-clock timing."
The change is confined to the six test files the issue names:
- geom: the tangent chain of a helix is a ratio (750 pieces against 3 000)
instead of a limit of 200 ms.
- io: the placement budget is spent inside the reader, so the clock is gone.
- ui-egui: the classification of many faces is a ratio (900 against 3 600)
instead of a limit of 10 s.
- engine: the clearance measurement drops its 30 s limit; the boolean that
gives up reports itself.
- engine: the fillet beside a modelled thread is a ratio (a 1 mm thread
against an 8 mm one) instead of a limit of 30 s.
- ui-egui: the window frame budget goes from 250 ms to 20 s, the limit #6072
gave its own probe.
The helper is the one #649 wrote, copied into the crates that need it, with
the noise of a run as a parameter.
* claim: #5329
* Update Links: show which linked design it reads, off the window thread (#5329)
Update Links read and rebuilt every linked design on the window thread, so the
window froze, with nothing on screen, until it finished. From the toolbar it now
runs as a file operation: off the window thread, with the overlay naming the
linked design being read (cover (2 of 3)), its rebuild step and progress, and
Cancel. The assembly stays as it was until the update is in, and it lands as one
undo step. The command reports each design through doc::progress::item.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
---------
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
The app's background loader (file_load::control) kept only `up` and
`names` of a control-channel open or import, so file.insert_step's
`matrix` and `name` were dropped and the part landed at the origin, and
file.insert_mesh lost all its options. It keeps every parameter but the
path, as given; each command checks them as it does when run directly.
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
* claim: #5150
* Stand it up: don't offer it for SolidCraft's own STEP files (#5150)
STEP replies from file.insert_step and doc.open now carry the file's
originating system, and the window skips the stand-up offer when it is
exactly SolidCraft, as SolidCraft's STEP export writes it.
* Stand up Y-up STEP and IGES files from SolidWorks automatically
The STEP header (originating system, preprocessor version, FILE_DESCRIPTION) and the IGES
global section's native system ID say which program wrote a file. A SolidWorks header means
Y up: the import's component is stood up as it opens, as one undo step, and the message offers
Undo. SolidCraft's own files are left alone; an unknown exporter keeps the offer.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
---------
Co-authored-by: Ray <raykholo@users.noreply.github.com>
Co-authored-by: Claude Sonnet 5.5 <noreply@anthropic.com>
* Open: show the design as its bodies are meshed, off the UI thread (#3053)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* Open: hold screenshots until the design is meshed; profile lines
* Tests: time-bounded opens
* Open: a Loading parts n/N note while bodies are meshed
* Open: frame the design from outlines while it goes into the window
* Outline bounds: vertices and edges only; test
* Frame watch: the window thread's frame times by open phase (SOLIDCRAFT_PROFILE_FRAMES)
* Open: the picture grows in mesh order and stays once complete; refreshes pace themselves; named frame steps; watchdog test
* Open: outlines measured on the file worker and kept per body
* Open: draw the Home picture under the opened file's own key once meshed
* Format the open wait
---------
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
file.insert_step and doc.open on a STEP file take `up` (turn a Y-up file so its up is +Z) and `names` (names for the imported bodies). The MCP tool and the app's control requests pass them through; an import without them works as before. Tests in the kernel's STEP reader, the engine, MCP and the file-load UI; docs/step-import.md and docs/mcp.md describe both.
The loading card was centred on its height, so Cancel moved when the progress bar or the saved preview appeared, and a click could miss it. That's what made the Cancel test flaky on slow runners. The card is now anchored at its top, Cancel sits in the heading row and the progress bar is always shown. Progress::hold_at lets the test hold a load at a feature boundary until it's cancelled.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The loading box was a full-window modal whose backdrop covered the custom title bar. It is now a light overlay under the title bar, so dragging, snapping, resizing and the window buttons keep working during open, import and recovery. The timeline rebuild shows feature N of M, and Cancel or Esc stops it at the next feature (solidcraft_doc::progress). Recovery restore now runs off the window thread too. A control or MCP doc.open or import is answered once the file is in and doesn't block frames; edits sent meanwhile wait their turn. The web build still opens in place.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>